diff options
Diffstat (limited to 'drivers/net/ethernet/intel/i40e/i40e_main.c')
-rw-r--r-- | drivers/net/ethernet/intel/i40e/i40e_main.c | 56 |
1 files changed, 52 insertions, 4 deletions
diff --git a/drivers/net/ethernet/intel/i40e/i40e_main.c b/drivers/net/ethernet/intel/i40e/i40e_main.c index cc8c0aeab9bb..3e595adfb0bf 100644 --- a/drivers/net/ethernet/intel/i40e/i40e_main.c +++ b/drivers/net/ethernet/intel/i40e/i40e_main.c @@ -39,7 +39,7 @@ static const char i40e_driver_string[] = #define DRV_VERSION_MAJOR 1 #define DRV_VERSION_MINOR 3 -#define DRV_VERSION_BUILD 38 +#define DRV_VERSION_BUILD 46 #define DRV_VERSION __stringify(DRV_VERSION_MAJOR) "." \ __stringify(DRV_VERSION_MINOR) "." \ __stringify(DRV_VERSION_BUILD) DRV_KERN @@ -6837,6 +6837,15 @@ static void i40e_reset_and_rebuild(struct i40e_pf *pf, bool reinit) if (pf->flags & I40E_FLAG_MSIX_ENABLED) ret = i40e_setup_misc_vector(pf); + /* Add a filter to drop all Flow control frames from any VSI from being + * transmitted. By doing so we stop a malicious VF from sending out + * PAUSE or PFC frames and potentially controlling traffic for other + * PF/VF VSIs. + * The FW can still send Flow control frames if enabled. + */ + i40e_add_filter_to_drop_tx_flow_control_frames(&pf->hw, + pf->main_vsi_seid); + /* restart the VSIs that were rebuilt and running before the reset */ i40e_pf_unquiesce_all_vsi(pf); @@ -8732,12 +8741,22 @@ int i40e_is_vsi_uplink_mode_veb(struct i40e_vsi *vsi) return 1; veb = pf->veb[vsi->veb_idx]; + if (!veb) { + dev_info(&pf->pdev->dev, + "There is no veb associated with the bridge\n"); + return -ENOENT; + } + /* Uplink is a bridge in VEPA mode */ - if (veb && (veb->bridge_mode & BRIDGE_MODE_VEPA)) + if (veb->bridge_mode & BRIDGE_MODE_VEPA) { return 0; + } else { + /* Uplink is a bridge in VEB mode */ + return 1; + } - /* Uplink is a bridge in VEB mode */ - return 1; + /* VEPA is now default bridge, so return 0 */ + return 0; } /** @@ -10164,6 +10183,7 @@ static int i40e_probe(struct pci_dev *pdev, const struct pci_device_id *ent) int err; u32 len; u32 i; + u8 set_fc_aq_fail; err = pci_enable_device_mem(pdev); if (err) @@ -10428,6 +10448,25 @@ static int i40e_probe(struct pci_dev *pdev, const struct pci_device_id *ent) dev_info(&pdev->dev, "setup_pf_switch failed: %d\n", err); goto err_vsis; } + + /* Make sure flow control is set according to current settings */ + err = i40e_set_fc(hw, &set_fc_aq_fail, true); + if (set_fc_aq_fail & I40E_SET_FC_AQ_FAIL_GET) + dev_dbg(&pf->pdev->dev, + "Set fc with err %s aq_err %s on get_phy_cap\n", + i40e_stat_str(hw, err), + i40e_aq_str(hw, hw->aq.asq_last_status)); + if (set_fc_aq_fail & I40E_SET_FC_AQ_FAIL_SET) + dev_dbg(&pf->pdev->dev, + "Set fc with err %s aq_err %s on set_phy_config\n", + i40e_stat_str(hw, err), + i40e_aq_str(hw, hw->aq.asq_last_status)); + if (set_fc_aq_fail & I40E_SET_FC_AQ_FAIL_UPDATE) + dev_dbg(&pf->pdev->dev, + "Set fc with err %s aq_err %s on get_link_info\n", + i40e_stat_str(hw, err), + i40e_aq_str(hw, hw->aq.asq_last_status)); + /* if FDIR VSI was set up, start it now */ for (i = 0; i < pf->num_alloc_vsi; i++) { if (pf->vsi[i] && pf->vsi[i]->type == I40E_VSI_FDIR) { @@ -10585,6 +10624,15 @@ static int i40e_probe(struct pci_dev *pdev, const struct pci_device_id *ent) i40e_aq_str(&pf->hw, pf->hw.aq.asq_last_status)); pf->hw.phy.phy_types = le32_to_cpu(abilities.phy_type); + /* Add a filter to drop all Flow control frames from any VSI from being + * transmitted. By doing so we stop a malicious VF from sending out + * PAUSE or PFC frames and potentially controlling traffic for other + * PF/VF VSIs. + * The FW can still send Flow control frames if enabled. + */ + i40e_add_filter_to_drop_tx_flow_control_frames(&pf->hw, + pf->main_vsi_seid); + /* print a string summarizing features */ i40e_print_features(pf); |