diff options
author | Robert Marko <robert.marko@sartura.hr> | 2020-09-13 19:21:40 +0200 |
---|---|---|
committer | Seth Forshee <seth.forshee@canonical.com> | 2020-11-10 08:25:18 -0600 |
commit | 5bcafa3c6a914610ac8397dffda036e4d4feb2b2 (patch) | |
tree | 89968282531cf11d13b4a24aca852b34355e7c56 | |
parent | ede87f56c6c69652d30e09ce9d9fc07b8dea3388 (diff) | |
download | external_wireless-regdb-5bcafa3c6a914610ac8397dffda036e4d4feb2b2.tar.gz external_wireless-regdb-5bcafa3c6a914610ac8397dffda036e4d4feb2b2.tar.bz2 external_wireless-regdb-5bcafa3c6a914610ac8397dffda036e4d4feb2b2.zip |
wireless-regdb: Update regulatory rules for Croatia (HR)
Croatian Regulatory Authority for Network Industries (HAKOM) has
updated the general licenses OD-85 and OD-86 with the new OD-85a
and OD-86a versions.
These introuduce the following changes:
* Outdoor usage for 5150-5250 and 5250-5350 MHz ranges is permitted
* 5150-5250 MHz range TPC requirment was dropped and power output raised to 200mW
OD-85a: https://www.hakom.hr/UserDocsImages/op%C4%87e%20dozvole%20prosinac%202009.g/Opca_dozvola_85a.pdf
OD-86a: https://www.hakom.hr/UserDocsImages/op%C4%87e%20dozvole%20prosinac%202009.g/Opca_dozvola_86a.pdf
Signed-off-by: Robert Marko <robert.marko@sartura.hr>
Cc: Luka Perkov <luka.perkov@sartura.hr>
Signed-off-by: Seth Forshee <seth.forshee@canonical.com>
-rw-r--r-- | db.txt | 4 |
1 files changed, 2 insertions, 2 deletions
@@ -694,8 +694,8 @@ country HR: DFS-ETSI # Harmonized CEPT countries (July 2019): https://www.ecodocdb.dk/download/25c41779-cd6e/Rec7003e.pdf # HR: http://tablice.hakom.hr:8080/vis?lang=en (2400 - 2483.5 @ 40), (100 mW) - (5150 - 5250 @ 80), (200 mW), NO-OUTDOOR, AUTO-BW, wmmrule=ETSI - (5250 - 5350 @ 80), (100 mW), NO-OUTDOOR, DFS, AUTO-BW, wmmrule=ETSI + (5150 - 5250 @ 80), (200 mW), AUTO-BW, wmmrule=ETSI + (5250 - 5350 @ 80), (200 mW), DFS, AUTO-BW, wmmrule=ETSI (5470 - 5725 @ 160), (500 mW), DFS, wmmrule=ETSI # short range devices (ETSI EN 300 440-1) (5725 - 5875 @ 80), (25 mW) |