aboutsummaryrefslogtreecommitdiffstats
path: root/drivers/thermal
diff options
context:
space:
mode:
authorDaniel Lezcano <daniel.lezcano@linaro.org>2021-03-14 12:13:31 +0100
committerDaniel Lezcano <daniel.lezcano@linaro.org>2021-03-15 04:47:04 +0100
commitf8d354e821b268c23a6cd548b7154e55c3954496 (patch)
treeba3ae1ecdfce2756f6f1a05edf93d80fb3595719 /drivers/thermal
parentef37d1f9acb57b7a5993e93ae582ba5f4108919e (diff)
downloadlinux-backports-f8d354e821b268c23a6cd548b7154e55c3954496.tar.gz
linux-backports-f8d354e821b268c23a6cd548b7154e55c3954496.tar.bz2
linux-backports-f8d354e821b268c23a6cd548b7154e55c3954496.zip
thermal/drivers/devfreq_cooling: Use device name instead of auto-numbering
Currently the naming of a cooling device is just a cooling technique followed by a number. When there are multiple cooling devices using the same technique, it is impossible to clearly identify the related device as this one is just a number. For instance: thermal-devfreq-0 thermal-devfreq-1 etc ... The 'thermal' prefix is redundant with the subsystem namespace. This patch removes the 'thermal' prefix and changes the number by the device name. So the naming above becomes: devfreq-5000000.gpu devfreq-1d84000.ufshc etc ... Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Reviewed-by: Lukasz Luba <lukasz.luba@arm.com> Link: https://lore.kernel.org/r/20210314111333.16551-3-daniel.lezcano@linaro.org
Diffstat (limited to 'drivers/thermal')
-rw-r--r--drivers/thermal/devfreq_cooling.c25
1 files changed, 8 insertions, 17 deletions
diff --git a/drivers/thermal/devfreq_cooling.c b/drivers/thermal/devfreq_cooling.c
index fed3121ff2a1..fb250ac16f50 100644
--- a/drivers/thermal/devfreq_cooling.c
+++ b/drivers/thermal/devfreq_cooling.c
@@ -14,7 +14,6 @@
#include <linux/devfreq_cooling.h>
#include <linux/energy_model.h>
#include <linux/export.h>
-#include <linux/idr.h>
#include <linux/slab.h>
#include <linux/pm_opp.h>
#include <linux/pm_qos.h>
@@ -25,11 +24,8 @@
#define HZ_PER_KHZ 1000
#define SCALE_ERROR_MITIGATION 100
-static DEFINE_IDA(devfreq_ida);
-
/**
* struct devfreq_cooling_device - Devfreq cooling device
- * @id: unique integer value corresponding to each
* devfreq_cooling_device registered.
* @cdev: Pointer to associated thermal cooling device.
* @devfreq: Pointer to associated devfreq device.
@@ -51,7 +47,6 @@ static DEFINE_IDA(devfreq_ida);
* @em_pd: Energy Model for the associated Devfreq device
*/
struct devfreq_cooling_device {
- int id;
struct thermal_cooling_device *cdev;
struct devfreq *devfreq;
unsigned long cooling_state;
@@ -363,7 +358,7 @@ of_devfreq_cooling_register_power(struct device_node *np, struct devfreq *df,
struct thermal_cooling_device *cdev;
struct device *dev = df->dev.parent;
struct devfreq_cooling_device *dfc;
- char dev_name[THERMAL_NAME_LENGTH];
+ char *name;
int err, num_opps;
dfc = kzalloc(sizeof(*dfc), GFP_KERNEL);
@@ -407,30 +402,27 @@ of_devfreq_cooling_register_power(struct device_node *np, struct devfreq *df,
if (err < 0)
goto free_table;
- err = ida_simple_get(&devfreq_ida, 0, 0, GFP_KERNEL);
- if (err < 0)
+ cdev = ERR_PTR(-ENOMEM);
+ name = kasprintf(GFP_KERNEL, "devfreq-%s", dev_name(dev));
+ if (!name)
goto remove_qos_req;
- dfc->id = err;
-
- snprintf(dev_name, sizeof(dev_name), "thermal-devfreq-%d", dfc->id);
-
- cdev = thermal_of_cooling_device_register(np, dev_name, dfc,
+ cdev = thermal_of_cooling_device_register(np, name, dfc,
&devfreq_cooling_ops);
+ kfree(name);
+
if (IS_ERR(cdev)) {
err = PTR_ERR(cdev);
dev_err(dev,
"Failed to register devfreq cooling device (%d)\n",
err);
- goto release_ida;
+ goto remove_qos_req;
}
dfc->cdev = cdev;
return cdev;
-release_ida:
- ida_simple_remove(&devfreq_ida, dfc->id);
remove_qos_req:
dev_pm_qos_remove_request(&dfc->req_max_freq);
free_table:
@@ -527,7 +519,6 @@ void devfreq_cooling_unregister(struct thermal_cooling_device *cdev)
dev = dfc->devfreq->dev.parent;
thermal_cooling_device_unregister(dfc->cdev);
- ida_simple_remove(&devfreq_ida, dfc->id);
dev_pm_qos_remove_request(&dfc->req_max_freq);
em_dev_unregister_perf_domain(dev);