diff options
author | Bjorn Helgaas <bjorn.helgaas@hp.com> | 2005-10-24 22:11:57 +0100 |
---|---|---|
committer | Russell King <rmk+kernel@arm.linux.org.uk> | 2005-10-24 22:11:57 +0100 |
commit | add7b58e7558dd2894f3c17ca8574099fcba5c15 (patch) | |
tree | c9f5b250f8b1df7476d6fb36e311dc0b4bf5c005 /include/linux/pci_ids.h | |
parent | d5c5d8fe32a4b9b14363c6031061e98e26da59a2 (diff) | |
download | kernel_samsung_smdk4412-add7b58e7558dd2894f3c17ca8574099fcba5c15.tar.gz kernel_samsung_smdk4412-add7b58e7558dd2894f3c17ca8574099fcba5c15.tar.bz2 kernel_samsung_smdk4412-add7b58e7558dd2894f3c17ca8574099fcba5c15.zip |
[SERIAL] support the Exsys EX-4055 4S four-port card
Tested by Wolfgang Denk with this device:
00:0f.0 Network controller: PLX Technology, Inc. PCI <-> IOBus Bridge (rev 01)
Subsystem: Exsys EX-4055 4S(16C550) RS-232
Control: I/O+ Mem+ BusMaster- SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B-
Status: Cap- 66Mhz- UDF- FastB2B+ ParErr- DEVSEL=medium >TAbort- <TAbort- <MAbort- >SERR- <PERR-
Interrupt: pin A routed to IRQ 10
Region 0: Memory at 80100000 (32-bit, non-prefetchable) [size=128]
Region 1: I/O ports at 7080 [size=128]
Region 2: I/O ports at 7400 [size=32]
00:0f.0 Class 0280: 10b5:9050 (rev 01)
Subsystem: d84d:4055
Results with this patch:
Serial: 8250/16550 driver $Revision: 1.90 $ 32 ports, IRQ sharing enabled
ttyS0 at I/O 0x3f8 (irq = 4) is a 16550A
PCI: Found IRQ 10 for device 0000:00:0f.0
ttyS4 at I/O 0x7400 (irq = 10) is a 16550A
ttyS5 at I/O 0x7408 (irq = 10) is a 16550A
ttyS6 at I/O 0x7410 (irq = 10) is a 16550A
ttyS7 at I/O 0x7418 (irq = 10) is a 16550A
Signed-off-by: Bjorn Helgaas <bjorn.helgaas@hp.com>
Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>
Diffstat (limited to 'include/linux/pci_ids.h')
-rw-r--r-- | include/linux/pci_ids.h | 1 |
1 files changed, 1 insertions, 0 deletions
diff --git a/include/linux/pci_ids.h b/include/linux/pci_ids.h index f74ed946247..ca0691c319a 100644 --- a/include/linux/pci_ids.h +++ b/include/linux/pci_ids.h @@ -2696,6 +2696,7 @@ #define PCI_SUBVENDOR_ID_EXSYS 0xd84d #define PCI_SUBDEVICE_ID_EXSYS_4014 0x4014 +#define PCI_SUBDEVICE_ID_EXSYS_4055 0x4055 #define PCI_VENDOR_ID_TIGERJET 0xe159 #define PCI_DEVICE_ID_TIGERJET_300 0x0001 |