diff options
author | Roland Knall <roland.knall@br-automation.com> | 2018-07-16 16:10:46 +0200 |
---|---|---|
committer | Roland Knall <rknall@gmail.com> | 2018-07-16 14:15:50 +0000 |
commit | 74a747fd527db474f4703eed69c843aa5a44804d (patch) | |
tree | 0a5eda7db7ba13a2d618b56e9cf76f091753e2f2 /docbook | |
parent | 4eb5b535ecb9cea390cc3ebad2097400f303b9ba (diff) | |
download | wireshark-74a747fd527db474f4703eed69c843aa5a44804d.tar.gz wireshark-74a747fd527db474f4703eed69c843aa5a44804d.tar.bz2 wireshark-74a747fd527db474f4703eed69c843aa5a44804d.zip |
extcap: Correct doc structure
Some issues in the developer doc have been corrected
Change-Id: I0d60e9080ef582dafa12607fb5ea43a8ae5d2d0f
Reviewed-on: https://code.wireshark.org/review/28727
Reviewed-by: Roland Knall <rknall@gmail.com>
Diffstat (limited to 'docbook')
-rw-r--r-- | docbook/wsdg_src/WSDG_chapter_capture.asciidoc | 12 |
1 files changed, 6 insertions, 6 deletions
diff --git a/docbook/wsdg_src/WSDG_chapter_capture.asciidoc b/docbook/wsdg_src/WSDG_chapter_capture.asciidoc index 4b5af79ee0..1c1a437b47 100644 --- a/docbook/wsdg_src/WSDG_chapter_capture.asciidoc +++ b/docbook/wsdg_src/WSDG_chapter_capture.asciidoc @@ -478,7 +478,7 @@ The protocol used to communicate over the control pipes has a fixed size header Payload length + 2 bytes for control number and command. .Control Number: - Unique number to identify the control. This number also gives the order of the controls in the interface toolbar. + Unique number to identify the control. This number also gives the order of the controls in the interface toolbar. .Commands and application for controls [cols="1,2,3"] @@ -497,15 +497,15 @@ The protocol used to communicate over the control pipes has a fixed size header |9 |Error message |none |=== - Payload Length: - The length of the following payload. Maximum length is 65535 bytes. +.Payload Length: + The length of the following payload. Maximum length is 65535 bytes. -The Initialized command will be sent from the GUI to the extcap utility when all +The `Initialized` command will be sent from the GUI to the extcap utility when all user changed control values are sent after starting a capture. This is an indication that the GUI is ready to receive control values. -The GUI will only send Initialized and Set commands. The extcap utility shall not -send the Initialized command. +The GUI will only send `Initialized` and `Set` commands. The extcap utility shall not +send the `Initialized` command. Messages with unknown control number or command will be silently ignored. |